CJVPD - 881-7488 KODAK PHOTOLIFE PHOTO / ELECTRONIC LITHIUM BATTERY
- MSDS: CJVPD
- Manufacturer: EASTMAN KODAK COMPANY
- Product Name: 881-7488 KODAK PHOTOLIFE PHOTO / ELECTRONIC LITHIUM BATTERY
- National Stock Number: 6135-01-210-8715
Product Identification
Product ID:881-7488 KODAK PHOTOLIFE PHOTO / ELECTRONIC LITHIUM BATTERY
MSDS Date:01/27/1999
FSC:6135
NIIN:01-210-8715
Status Code:A
MSDS Number: CJVPD
Responsible Party
ROCHESTER, NY 14650
US
Emergency Phone: 716-722-5151
Info Phone: 716-722-5151
Cage: 19139
Contractor
Telephone: 716-722-5151/(800) 242-2424
Cage: 19139
Ingredients
MANGANESE DIOXIDE
CAS: 1313-13-9
RTECS: OP0350000
OSHA PEL C5 MG/M3
ACGIH TLV: 5 MG/M3
PROPYLENE CARBONATE
CAS: 108-32-7
RTECS: FF9650000
1,2-DIMETHOXYETHANE
CAS: 110-71-4
RTECS: KI1451000
LITHIUM
CAS: 7439-93-2
RTECS: OJ5540000
STEEL CASING
PLASTIC
Hazards
LD50 LC50 Mixture:NONE PROVIDED BY MFR.
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IF BATTERY IS DAMAGED SO AS TO RELEASE
CONTENTS- INHALATION: HARMFUL IF INHALED. MAY CAUSE IRRITATION TO
THE MUCOUS MEMBRANES & UPPER RESPIRATORY TRACT. EYES: CONTACT WITH
ELECTROLYTE (LIQUID) CAUSES BURNS. VAPORS OR FUMES MAY CAUSE
IRRITATION. CONTACT WITH METAL FRAGMENTS MAY CAUSE BURNS OR
MECHANICAL INJURY. SKIN: CONTACT WITH ELECTROLYTE (LIQUID) CAUSES
BURNS. CONTACT WITH METAL FRAGMENTS MAY C AUSE BURNS OR MECHANICAL
INJURY. HARMFUL IF ABSORBED THROUGH SKIN. VAPORS OR FUMES MAY CAUSE
IRRITATION. INGESTION: ALL BATTERIES MAY BE HARMFUL IF SWALLOWED.
MAY CAUSE BURNS OF THE GASTRONTESTINAL TR ACT.
Explanation of Carcinogenicity:COMPONENTS PRESENT AT 0.1% OR MORE:
IARC: NONE. ACGHI: NONE. NPT: NONE. OSHA: NONE.
First Aid
First Aid:FOR VENTED/LEAKING BATTERY- INHALATION: VAPORS OR FUMES ARE
IRRITATING TO RESPIRATORY TRACT, MOVE TO FRESH AIR. TREAT
SYMPTOMATICALLY, GET MEDICAL ATTENTION IF SYSTOMS PERSIST. EYES:
IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINS. GET
MEDICAL ATTENTION IMMEDIATELY. SKIN: IMMEDIATELY REMOVE METAL
FRAGMENTS & FLUSH SKIN WITH PLENTY OF WATER FOR AT LEAST 15 MINS
WHILE REMOVING CONTAMINAT ED CLOTHING & SHOES. GET MEDICAL
ATTENTION IMMEDIATELY. INGESTION: CALL A PHYSICIAN OR POISON
CONTROL CENTER IMMEDIATELY FOR ANY ACTUAL OR SUSPECTED INGESTION.
DO NOT INDUCE VOMTING. RINSE MOUTH WITH WATER.
Fire Fighting
Extinguishing Media:FLOOD WITH WATER. DO NOT USE CARBON MONOXIDE OR
HALON TYPE EXTINGUISHER. USE CAUTION DURING WATER APPLICATION AS
BURNING PIECES OF LITHIUM MAY BE EJECTED FROM FIRE.
Fire Fighting Procedures:FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS. WEAR SELF-CONTAINED BREATHING APPRATATUS
AND PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:FIRE OR HIGH TEMPERATURES MAY CAUSE
BATTERY TO FLAME OR LEAK FLAMMABLE AND HAZARDOUS VAPORS. DAMAGED OR
OPENED BATTERIES CAN RESULT IN RAPID HEADING AND THE RELEASE OF
FLAMMABLE AND HAZARDOUS VAPORS.
Accidental Release
Neutralizing Agent:NONE PROVIDED BY MFR.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. PROTECT
FROM DIRECT SUNLIGHT. STORAGE ABOVE 21C (70F) MAY AFFECT PRODUCT
QUALITY. DO NOT STORE IN A MANNER THAT ALLOWS TERMINALS TO SHORT
CIRCUIT. EXTENDED SHORT CIRCUITING CREATES HIGH TEMPERATURES IN
THE BATTERY. HIGH TEMPS CAN CAUSE LEAKAGE, EXPLOSION, AND/OR FLAME.
Other Precautions:SHORT CIRCUITING MAY REDUCE BATTERY SERVICE LIFE.
Exposure Controls
Respiratory Protection:NONE SHOULD BE NEEDED
Ventilation:SUPPLEMENTAS VENTILATION MAY BE NEEDED IN SPECIAL
CIRCUMSTANCES TO CONTROL FUMES/VAPORS TO AN ACCEPTABLE LEVEL.
Protective Gloves:IMPERVIOUS GLOVES
Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS OR GOGGLES
Other Protective Equipment:WSHING FACILITIES.
Work Hygienic Practices:WASH CONTAMINATED CLOTHING BEFORE REUSE.
DESTROY OR THOROUGHLY CLEAN CONTAMINATED SHOES.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:Z6
Vapor Pres:NEGLIGIBLE
Solubility in Water:INSOLUBLE
Appearance and Odor:SOLID, ODORLESS
Stability
Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:STABLE UNDER NORMAL CONDITIONS OF USE.
Hazardous Decomposition Products:OXIDES OF LITHIUM, OXIDES OF
MANGANESE, CARBON DIOXIDE, CARBON MONOXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DO NOT INCRNERATE OR EXPOSE TO FIRE. DISCHARGE,
TREATMENT, OR DISPOSAL MAY BE SUBJECT TO NATIONAL, STATE, OR LOCAL
LAWS.
Toxicology
Toxicological Information:1,2-DIMETHOXYETHANE: CAN CAUSE ADVERSE
REPRODUCTIVE EFFECTS SUCH AS BIRTH DEFECTS, MISCARRIAGES, OR
INFERTILITY.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
Ecology
Ecological:THIS MATERIAL HAS NOT BEEN TESTED FOR ENVIRONMENTAL EFFECTS.
Transport
Transport Information:FOR TRANSPORTATION INFORMATION REGARDING THIS
PRODUCT CALL THE KODAK WORLDWIDE TRANSPORTATION HAZMAT HOT LINE:
716-722-2400 BETWEEN 3 AM AND 5 PM (EASTERN STANDARD TIME), MONDAY
THROUGH FRIDAY.